Main page > Designing 
DESIGNING

Operated project works:

  • Preparing of design estimates of automatic installations of fire extinguishing (AIFE) for high-floored constructions, storages of fuels and lubricants and inflatable liquids - with application of robotized complexes RFC; installations of load platforms' fire extinguishing and wharfage by use of remote-controlled fire monitors LSD or oscillator devices.

    Watering of protected area can be operated by foam of low ratio, compact, dispersed and fine-air water streams.

  • Design works on other types of automatic installations, including module and automatic installations of fire alarm.
    The project can also include the following works:
    1. Pumping facility of water (foam) extinguishing.
      - technological part;
      - electric-technical part;
      - specifications for structural drawing, water supply, electricity supply.
    2. Automatic installation of fire alarm.
      - setting of alarm, which initiates extinguishing installation's start up;
      - installation of fire alarm, which protects units rooms without equipping with AIFE;
      - installation of hand-held fire annunciators;
      - connection with unit's other engineering systems (command signals, electricity supply).
    3. Technological part of AIFE project.
      - hydraulic calculation; - distribution of fire robots network, fire monitors, fire hoses, sprinkler and drencher sections and so on;
      - specifications for fire robots' and monitors' service floor.
    4. Electrotechnical project part.
      - schemes and placing of AIFE equipment;
      - connection with other engineering systems of the unit (command signals, electricity supply).
    5. The system of teleobservation.
      - Schemes of connections and placing of system equipment, it provides observation in case of fire.
    6. Estimate documents.
  • Besides the main activity, the design department provides following services:
    - the choice of the best FR production application variant and project maintenance for the design departments;
    - help in fire technology choice and placing recommendations for the private customers.

  • ATTENTION: In connection with a fact, that software is being elaborated individually, taking into account fire robots’, annunciators’ and other equipment’s location, “FR”-SP examines every project with application of RFC.

Engineered projects:

In 2005 "FR"-Jsc. operated new works in application of fire technology for the units, where application of traditional installations of water and foam extinguishing is irrational.

Approximate area 7000 sq.m.
  • Type designs of installations of automatic fire extinguishing with application of robotized fire complex RFC for inflatable constructions of the approximate area:

    1000 sq. m. - project 32-05-1-ÀÏÒ;
    3000 sq. m. - project 32-05-2-ÀÏÒ;
    7000 sq. m. - project 32-05-3-ÀÏÒ...


    more...
Hangar per 5 airplanes
  • projects of foam fire extinguishing installations with application of robotized fire complex RFC for airplanes and helicopter hangars;

    "FR"-Jsc. has prepares the work project of automatic installation of foam extinguishing and water cooling with application of Robotized fire complex (RFC) according to special technical requirements for design of fire safety system for a hangar per 5 airplanes...



    more...


  • technical decisions "Automatic installation of water extinguishing in oil-filled power autotransformers on Russian energy units with application of oscillator fire monitors, manufactured by FR-Jsc."

    In 2008 "FR"-Jsc. has elaborated technical decisions "Automatic installation of water extinguishing in oil-filled power autotransformers on Russian energy units with application of oscillator fire monitors, manufactured by FR-Jsc." and successfully held the prototype test in the present of reputable board with representatives from "The Institute "Energoproject", "The Engineering centre of EEC", the branch of "The Institute "Teploelektroproject", Russian EMERCOM




    The recommended variant of remote-controlled fire monitors' application:

  • Explosion-proof modification Explosion-proof modification

    Remote-controlled fire monitors of Explosion-proof modification can be used in consistence of stationary, non-automatic installations of foam extinguishing and water cooling of reservoir parks and load railway platforms (ÑÍèÏ 2.11.03-93 "Oil and oil production storrages. Fire-prevention regulations") and other units of implosive areas…



    more...

  • In usual modification

    Remote-controlled fire monitors of usual modification can be applied in consistence of stationary non-automatic installations of foam extinguishing and water cooling of different units…

    more...

ALL COMPLETED PROJECTS >>>